Industry informationHome>Industry information > Winter maintenance of diesel engine water pump

Winter maintenance of diesel engine water pump

Time:2024-12-18 11:09:55  Edit:HuaQuan


The maintenance of diesel engine water pump in winter mainly includes the following aspects:

1. Temperature monitoring and antifreeze: In winter, when the temperature is low, the water in the water pump and its pipes is prone to freezing. Therefore, in non working conditions, the water should be drained and the water pump unit should be insulated if possible. Installing temperature monitoring equipment can prevent the unit from freezing.

2. Preheating: Preheating the water pump before starting it in a cold environment can effectively prevent starting difficulties or damage caused by low temperature. The preheating method includes using a preheater to circulate and heat the coolant or directly heating the cylinder. Some advanced models are also equipped with remote preheating function, and users can start the preheating program in advance through the mobile app.

3. Check and replace lubricating oil: Check the lubrication system of the water pump unit in a timely manner and replace the lubricating oil as needed. Under low temperature conditions, the original lubricating oil may thicken, affecting the lubrication effect. It is necessary to ensure the use of lubricating oil suitable for low-temperature environments to maintain the smooth operation of the water pump.

4. Check the sealing and valves: Regularly check the sealing condition of the water pump to ensure that the sealing components will not leak due to shrinkage or expansion under temperature differences. At the same time, check whether the valves are working properly, especially the vent valve and drain valve, to ensure that they can respond quickly when needed.

5. Avoid cold start: The water pump should not be started directly after being stopped for a long time, especially when the temperature is low. A comprehensive inspection and appropriate preheating of the unit should be carried out first to prevent damage to the components due to cold start.

6. Remove accumulated water: Ensure that there is no residual water in the water pump and its piping system. Water accumulation not only increases the risk of icing, but may also cause rusting and corrosion of metal components.

7. Use antifreeze: In winter, appropriate antifreeze should be prepared according to the temperature and replaced every November. Antifreeze can effectively prevent coolant from freezing and protect the water pump from damage.

8. Insulation measures: For facilities such as water pumps, water pipes, and faucets exposed to cold outdoor environments, cotton wool, towels, or discarded clothing can be used for wrapping to achieve insulation effects. In addition, some high-end generator sets are equipped with intelligent temperature control systems that can automatically adjust the thickness of the insulation layer according to the external temperature.

For more information, please follow: http://www.fdjwang.com/

Sales hotline: +86 15905360672
WeChat customer service: +86 15905360672
Email address: huaquan@huaquanpower.com
Official website: https://www.huaquanpower.com
Production Base: No. 11666 Guting Street, Economic Development Zone, Weifang City, Shandong Province
Company Name:SHANDONG HUAQUAN POWER CO.,LTD