Long term storage of portable generators can lead to performance degradation and damage. During long-term parking, the mechanical components of the generator are prone to aging and rusting, the circuit system will accumulate dust and age, the fuel system will be damaged due to sediment formation and oil quality deterioration, and the battery performance will also decrease. In order to maintain the good condition of the generator, it is recommended to start and maintain it regularly, maintain a dry and ventilated storage environment, regularly inspect and replace fuel and lubricating oil, clean the inside and outside of the unit, and properly handle the electrical and fuel systems.

Maintenance and upkeep methods
1. Regular start-up and maintenance: Even if the generator is not frequently used, it should be started at regular intervals (such as monthly) to allow the mechanical components and circuit system to operate and lubricate. At the same time, vulnerable parts such as fuel filters and air filters should be inspected and replaced.
2. Cleaning and moisture prevention: The generator should be stored in a dry and ventilated environment, regularly cleaned of dust and oil stains on the surface, and the internal components should be blown with compressed air to keep the equipment clean and dry.
3. Fuel management: Regularly check and replace fuel, avoid using fuel that has been stored for too long, and prevent the deterioration of oil quality and the formation of deposits. At the same time, regularly clean the fuel system to ensure unobstructed fuel flow.
4. Battery maintenance: Regularly check the battery's charge status to ensure that it is charged to the appropriate level. Disconnect the battery connection wire, clean the terminals, and check the battery's charge status before restarting.

Possible problems and solutions of long-term parking
1. Aging and rusting of mechanical components: The mechanical components inside the generator, such as bearings, gears, pistons, etc., are prone to rusting and corrosion when not in use for a long time, leading to component damage. The solution is to regularly start and maintain, and maintain lubrication.
2. Dust accumulation and aging in circuits: Circuit systems are prone to accumulating dust, leading to poor contact or short circuits. The solution is to regularly clean the circuit system, keeping it dry and clean.
3. Fuel system issues: The fuel system is prone to damage due to the formation of deposits and deterioration of oil quality. The solution is to regularly inspect and replace the fuel, and clean the fuel system.
4. Decreased battery performance: The battery may deplete due to natural discharge, causing it to fail to start. The solution is to regularly check the battery's charge status and ensure that the battery is charged to the appropriate level before restarting.

Through the above measures, the service life of portable generators can be effectively extended and their performance can be maintained stable.
For more information, please follow: http://www.fdjwang.com/

Sales hotline: +86 15905360672
WeChat customer service: +86 15905360672
Email address: huaquan@huaquanpower.com
Official website: https://www.huaquanpower.com
Production Base: No. 11666 Guting Street, Economic Development Zone, Weifang City, Shandong Province
Company Name:SHANDONG HUAQUAN POWER CO.,LTD